Difference between revisions of "How to enable WebClient logging"

From support-works
Jump to navigation Jump to search
Line 18: Line 18:
  
 
:<code> define("_LOG_WC_SQL_ACTIVITY",false);
 
:<code> define("_LOG_WC_SQL_ACTIVITY",false);
#::<code> define("_LOG_WC_XMLMC_ACTIVITY",false);
+
#::define("_LOG_WC_XMLMC_ACTIVITY",false);
 
#::<code> define("_LOG_WC_XMLMC_RESPONSE",false);
 
#::<code> define("_LOG_WC_XMLMC_RESPONSE",false);
 
#::<code> define("_LOG_WC_5005_ACTIVITY",false);
 
#::<code> define("_LOG_WC_5005_ACTIVITY",false);
 
#::<code> define("_LOG_WC_SERVICE_ACTIVITY",false);
 
#::<code> define("_LOG_WC_SERVICE_ACTIVITY",false);

Revision as of 11:26, 30 January 2018




Status: Published
Version: 1.1
Authors: Hornbill Support
Applies to: All Versions of Supportworks

1.. Go to http://<servername>/sw/webclient/diagnose.php and forward the Diagnostic Report.

2.. In order to turn on logging for the webclient, the file <drive:>\Program Files\Hornbill\Supportworks Server\html\webclient\php\_wcconfig.php, will need to be edited. The follow entries will require the parameter false be set to true:

define("_LOG_WC_SQL_ACTIVITY",false);
  1. define("_LOG_WC_XMLMC_ACTIVITY",false);
    define("_LOG_WC_XMLMC_RESPONSE",false);
    define("_LOG_WC_5005_ACTIVITY",false);
    define("_LOG_WC_SERVICE_ACTIVITY",false);