{{Template:Basic Cover
 
{{Template:Basic Cover
 
| title=How to enable WebClient logging
 
| title=How to enable WebClient logging
Line 12: Line 9:
 
| applicableto=All Versions of Supportworks
 
| applicableto=All Versions of Supportworks
 
}}
 
}}
 +
 +
== How to enable WebClient logging ==
 +
 +
 +
The following are instructions on how to enable the logging, file locations and further information:
 +
 +
 +
 +
1..In order to turn on logging for the webclient, the file \Program Files\Hornbill\Supportworks Server\html\webclient\php\_wcconfig.php, will need to be edited.
 +
 +
 +
The follow entries will require the parameter false be set to true:
 +
 +
 +
::<code> define("_LOG_WC_SQL_ACTIVITY",false);</code>
 +
::<code> define("_LOG_WC_XMLMC_ACTIVITY",false);</code>
 +
::<code> define("_LOG_WC_XMLMC_RESPONSE",false);</code>
 +
::<code> define("_LOG_WC_5005_ACTIVITY",false);</code>
 +
::<code> define("_LOG_WC_SERVICE_ACTIVITY",false);</code>
 +
 +
 +
Once these entries have been changed and the file saved, each time that a session is started via a webclient login, a new log file will be created. 
 +
 +
 +
The file will be located at the following path; <dirve:>\Program Files\Hornbill\Supportworks Server\html\webclient\temporaryfiles\<session-id>
 +
 +
 +
The filename called webclient.log; will itself be located in a folder named using the <sessionid>, this will be unique for each weblient session. 
 +
 +
 +
The log file is a standard text file formatted using the standard Supportworks logging format, enabling the file to be opened via the Supportworks Log File Veiwer.

Latest revision as of 12:01, 30 January 2018



Status: Published
Version: 1.1
Authors: Hornbill Support
Applies to: All Versions of Supportworks

How to enable WebClient logging

The following are instructions on how to enable the logging, file locations and further information:


1..In order to turn on logging for the webclient, the file \Program Files\Hornbill\Supportworks Server\html\webclient\php\_wcconfig.php, will need to be edited.


The follow entries will require the parameter false be set to true:


define("_LOG_WC_SQL_ACTIVITY",false);
define("_LOG_WC_XMLMC_ACTIVITY",false);
define("_LOG_WC_XMLMC_RESPONSE",false);
define("_LOG_WC_5005_ACTIVITY",false);
define("_LOG_WC_SERVICE_ACTIVITY",false);


Once these entries have been changed and the file saved, each time that a session is started via a webclient login, a new log file will be created.


The file will be located at the following path; <dirve:>\Program Files\Hornbill\Supportworks Server\html\webclient\temporaryfiles\<session-id>


The filename called webclient.log; will itself be located in a folder named using the <sessionid>, this will be unique for each weblient session.


The log file is a standard text file formatted using the standard Supportworks logging format, enabling the file to be opened via the Supportworks Log File Veiwer.