# Enter the following via your preferred database query tool: | # Enter the following via your preferred database query tool: | ||
#:<pre>USE swdata | #:<pre>USE swdata</pre> | ||
#:<pre>SELECT MAX(callref) FROM opencall</pre> | #:<pre>SELECT MAX(callref) FROM opencall</pre> | ||
#:This will return the last call reference number used, please make a note of it. | #:This will return the last call reference number used, please make a note of it. |
Latest revision as of 16:13, 20 July 2015
You may find that the Supportworks Server service is unable to start and the following error is displayed in the swserver logs:
[ERROR]:[5972] Invalid callref: an entry in opencall is greater than nextcallref!
To resolve this issue the following steps should be completed on the Supportworks Application database:<br\>
- Enter the following via your preferred database query tool:
USE swdata
SELECT MAX(callref) FROM opencall
- This will return the last call reference number used, please make a note of it.
- Using the Interactive SQL tool, enter the the following, replacing the "####" with the callref value returned above:
USE sw_systemdb; [RETURN]
UPDATE system_counters SET count = #### WHERE name = 'nextcallreference'; [RETURN]