NextCallRef error on Server Service startup: Difference between revisions

From support-works
Jump to navigation Jump to search
No edit summary
No edit summary
 
(4 intermediate revisions by the same user not shown)
Line 6: Line 6:


# Enter the following via your preferred database query tool:
# Enter the following via your preferred database query tool:
#:<code>select MAX(callref) from opencall</code><br\>
#:<pre>USE swdata</pre>
# This will give you the last call reference number used, please make a note of it.
#:<pre>SELECT MAX(callref) FROM opencall</pre>
#:This will return the last call reference number used, please make a note of it.
Then go onto the Supportworks Server, Start > All Programs > Hornbill Core Services > Interactive SQL and enter the the following, replacing the "####" with the callref value returned above:
#Using the Interactive SQL tool, enter the the following, replacing the "####" with the callref value returned above:
 
#:<pre>USE sw_systemdb; [RETURN]</pre>
 
#:<pre>UPDATE system_counters SET count = #### WHERE name = 'nextcallreference'; [RETURN]</pre>
use sw_systemdb; [RETURN]
update system_counters set count = #### where name = 'nextcallreference'; [RETURN]

Latest revision as of 16:13, 20 July 2015

You may find that the Supportworks Server service is unable to start and the following error is displayed in the swserver logs:

[ERROR]:[5972] Invalid callref: an entry in opencall is greater than nextcallref!

To resolve this issue the following steps should be completed on the Supportworks Application database:<br\>

  1. Enter the following via your preferred database query tool:
    USE swdata
    SELECT MAX(callref) FROM opencall
    This will return the last call reference number used, please make a note of it.
  2. Using the Interactive SQL tool, enter the the following, replacing the "####" with the callref value returned above:
    USE sw_systemdb; [RETURN]
    UPDATE system_counters SET count = #### WHERE name = 'nextcallreference'; [RETURN]